EXP™ fittings, pre-column filter, guard columns & traps for "Extreme Pressure" Chromatography

easy installation, no tools required

Hardware rated to 1400 bar

tight connections

zero-dead-volume connection as swage adjusts to the different port depths of the various hardware

EXP™ Titanium Hybrid Ferrule  

one-piece design of well sealing PEEK and resilient Titanium

- repeated zero-dead-volume connections

- hand-tight to 600 bar, wrench tight to 1400 bar

EXP™ Titanium Hybrid Ferrule
15-24-03831 = Pack of 1 pcs.
15-24-03832 = Pack of 10 pcs.

Finger-Tight EXP™ Fittings & Hex Head EXP™ Fittings  

- for extreme high-pressure connections between
1/16" tubing and any 10-32 port

- hand-tight - rated to 1400 bar

10-32 Hand-Tight Nut & Titanium Hybrid Ferrule
15-20-03888 = Pack of 1 pcs.
15-20-03930 = Pack of 10 pcs.

10-32 standard Hex Head Nut
15-20-03833 = Pack of 1 pcs.

10-32 standard Hex Head Nut & Titanium Hybrid Ferrule
15-20-04120 = Pack of 1 pcs.
15-20-03834 = Pack of 10 pcs.

10-32 short Hex Head Nut
15-20-03839 = Pack of 1 pcs.

10-32 short Hex Head Nut & Titanium Hybrid Ferrule
15-20-03840 = Pack of 10 pcs.

10-32 long Hex Head Nut
15-20-03841 = Pack of 1 pcs.

10-32 long Hex Head Nut & Titanium Hybrid Ferrule
15-20-03842 = Pack of 10 pcs.

EXP™ Pre-Column Filter

 

- protects small-particle UHPLC columns at extreme pressure

- hand-tight filter replacement, without breaking the fluid
connections on the holder inlet/outlet

- hand-tight - rated to 1400 bar

- zero-dead-volume connection, low dispersion


EXP™ Pre-Column Filter Holder (Fittings included)
15-04-03837 = Pack of 1 pcs.


EXP™ Pre-Column Filter Cartridges, 0.5 µm
15-04-03093 = Pack of 5 pcs.
15-04-03094 = Pack of 10 pcs.

EXP™ Pre-Column Filter Cartridges, 0.2 µm
15-04-03096 = Pack of 5 pcs.
15-04-03097 = Pack of 10 pcs.

EXP™ Guard Columns  

The combination of low-dispersion and ultra high-pressure capabilities provides effective protection with negligible effects on retention time, plate count, and peak shape. Free-turn architecture allows the user to change cartridges by hand without breaking fluid connections on the holder inlet/outlet.

- protects your column, zero-dead-volume connection and pressure
rated to 1400 bar

- hand-tight guard replacement design

- is directly connected to the column; the auto-adjusting
Titanium Hybrid Ferrule guarantees ZDV column connection

- available packed with C18, C8, C4 and HILIC

EXP™ Guard Column Holder
for the direct connection with the column
15-02-03956 = Pack of 1 pcs.

EXP™ Guard Column Cartridges  

complete the product number on the right with the corresponding phase code below (**)

1.8 µm Phases
Code HA = C18
Code HB = C8
Code HC = C4
Code HD = Hilic

15-04100-**
Dimension 1.0 x 5 mm

15-04102-**
Dimension 1.5 x 5 mm

15-04104-**
Dimension 2.1 x 5 mm

15-04106-**
Dimension 3.0 x 5 mm

15-04108-**
Dimension 4.6 x 5 mm

3 µm Phases
Code HE = C18
Code HF = C8
Code HG = C4
Code HH = Hilic
Code HI = Phenyl-Hexyl
Code HJ = SAX
Code HK = SCX
HALO UHPLC Guard Column Cartridges pdf 567kb
EXP™ Trap Columns  

- for the quick removal of detergents or salts which
can affect the ionization process in MS work

- connects directly to any injection valve (with 10-32 threads)
or in-line with 1/16” stainless tubing and in combination with
the finger-tight OPTI-LOK™ EXP™ Fittings

- concentrates the sample directly on-line, allowing for
increased recovery of precious sample material compared
to off-line techniques

- readily lends itself to automation for high-throughput analysis
in UHPLC/MS applications

- Free-Turn® architecture allows the user to change
cartridges by hand without breaking fluid connections
on the holder inlet/outlet


EXP™ Direct Connect Holder


EXP™ In-Line Holder

EXP™ Holder for the direct connection to the injector valve
15-02-03956 (fittings included)

EXP™ Halter for in-line use
15-02-03946 (fittings included)

EXP™ All-In-One Holder Kit
includes: In-Line and Direct Connect Holder Components
15-02-04041

EXP™ Discovery Kit with HALO
includes EXP® Direct Connect or In-Line Holder and 3 HALO 2.7µm trap cartridge packs (3 per pack for a total of 9 Trap Cartridges)
(information on cartridges see below)

15-02-04042

EXP™ Trap Column Cartridges

complete the product number on the right with the corresponding phase code below (**)

2.7 µm HALO Phases
Code HA = C18
Code HB = C8
Code HD = Hilic
Code HE = RP-Amid
Code HF = Phenyl-Hexyl
Code HN = Peptide ES-C18


15-03964-**
4 µl bed volume
2 mL/min suggested max. load rate
Dimension 1.0 x 5 mm

15-03969-**
10 µl bed volume
4 mL/min suggested max. load rate
Dimension 1.5 x 5 mm

15-03973-**
20 µl bed volume
6 mL/min suggested max. load rate
Dimension 2.1 x 5 mm

15-03978-**
40 µl bed volume
8 mL/min suggested max. load rate
Dimension 3.0 x 5 mm

15-03983-**
100 µl bed volume
10 mL/min suggested max. load rate
Dimension 4.6 x 5 mm

3 µm EXP Phases
Code HG = C18
Code HH = C8
Code HI = C4
Code HJ = Hilic
Code HK = Phenyl-Hexyl
Code HL = SAX
Code HM = SCX


EXP Brochure
pdf 2.18 MB

Press Releases on EXP Products:

OPTI -TRAP EXP™ Trap Columns with HALO® for UHPLC Applications
pdf 187 kb

OPTI - PAK® EXP™ Stem Trap with HALO® fir UHPLC Applications
pdf 338 KB


LC Trapping Guide
pdf 2.6 MB

Optimize catalogue
pdf 30.3 MB

 
HPLC Columns & Accessories Index
HALO® Columns 2.7 µm - 90Å & 160Å
HALO®-5 Columns 5 µm - 90Å
HALO®-2 Columns 2 µm - 90Å
BioClass colums for the separation of peptides & proteins
HALO® Application
Catalogues
Optimize EXP™ Hardware & Accessories
© infochroma ag, Chräbelstr. 4, CH-6410 Goldau; Tel: +41 41 748 50 60, info@infochroma.ch