GC Capillary Columns


general purpose columns Polysiloxane Phases with 100% Dimethyl-, 5% Diphenyl- or an increasing share of Cyanopropyl Phenyl groups

Phenylene modified Polysiloxane Phases with minor column bleeding at high maximum temperature

polar Polyethylene Glycol Phases

Capillary Columns for temperature up to 350°C

100% Dimethylpolysiloxane or Phenyl-Polycarboran-Siloxane Phases

 
increasing Polarity
100% Dimethyl Polysiloxane
BP1

non- polar standard column, low bleed
for routine analysis

0.1 - 1.0 µm film thickness -60°C to 340/360°C
1.5 - 3.0 µm film thickness -60°C to 300/320°C
4.0 - 5.0 µm film thickness -60°C to 280/300°C

Column length: 10, 12, 15, 25, 30, 50, 60 m
Column lD: 0.1, 0.15, 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.25, 0.5, 1.0, 2.6, 3.0, 4.0, 5.0 µm

suitable for analysis of hydrocarbons, aromatics, pesticides, phenol, herbicides, amines
SolGel-1ms

robust high temperature non-polar phase for mass spectrometry applications

0.25µm film thickness 0°C to 340/360°C

Column length: 30, 60 m
Column lD: 0.25, 0.32 mm
Film Thickness 0.25 µm

recommended for highly active compounds
BPX1

100% polydimethylsiloxane
non-polar columns, low bleed
for Simulated Distillation in the petroleum industry

0.1 - 0.9 µm film thickness 30°C to 400°C
2.65 µm film thickness 30°C to 370°C

Column length: 6, 10 m
Column lD: 0.1, 0.53 mm
Film Thickness 0.1, 0.9, 2.65 µm

Aluminium Clad: 0.1 µm film thickness 30°C to 430°C

Column length: 5, 10 m
Column lD: 0.53 mm
Film Thickness 0.1, 0.17 µm

ASTM methods D2887 and D6532
BP1 PONA

non-polar phase for PONA analysis

0.5 µm film thickness -60°C to 280/300°C

Column length: 50, 100 m
Column lD: 0.15, 0.25 mm
Film Thickness 0.5 µm

Petroleum hydrocarbons, gasoline range hydrocarbons, MTBE
5% Phenyl Methylpolysiloxane
BP5

non-polar general purpose phase with excellent high temperature characteristics
popular columns used for a wide variety of applications

0.25 - 1.5 µm film thickness -60°C to 320/340°C
> 1.5 µm film thickness-60°C to 280/300°C

Column length: 12, 15, 25, 30, 50, 60 m
Column lD: 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.25, 0.5, 1.0 µm

Aromatics, pesticides, herbicides, drugs of abuse, hydrocarbons, GC/MS applications
5% Phenyl Polysilphenylene-siloxane
BPX5

MS-Premium, low bleed columns with a maximum temperature up to 370°C. Suitable for trace analysis of pesticides, drugs, hydrocarbons and phenols. The BPX5 phase has been designed for robustness and is suitable for over 80% of all routine analyses performed by chromatographers

0.25 - 1.5µm film thickness -40°C to 360/370°C
>1.5µm film thickness -40°C to 350/360°C

Column length: 6, 7, 10, 12, 15, 25, 30, 40, 50, 60 m
Column lD: 0.1, 0.15, 0.18, 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.1, 0.15, 0.18, 0.25, 0.4, 0.5, 1.0, 1.2, 3.0, µm

Comparison of Structure and Retention on various 5 % Phenyl Phases
The advantages of BX5, BX35 and BX50 Phases when analysing aromatic compounds
pdf 1.3 MB
5% Phenyl Polycarboran-siloxane
8% Phenyl Polycarboran-siloxane
HT5

unique high temperature phase suited for simulated distillation and other petroleum applications. This column is the highest temperature column available with a maximum temperature up to 480°C

0.1 - 0.5 µm film thickness 10°C to 380/400°C

Column length: 6, 10, 12, 15, 25, 30 m
Column lD: 0.22, 0.32, 0.53 mm
film thickness 0.1, 0.15, 0.5 µm

Aluminium Clad:
0.1 - 0.5µm film thickness 10°C to 460/480°C

Column length: 5, 6, 12, 25, 50 m
Column lD: 0.22, 0.32, 0.53 mm
Film Thickness 0.075, 0.1, 0.15, µm

simulated distillation, general hydrocarbon profiles, pesticides/herbicides, GC/MS applications
HT8

Unique high temperature phase suited for the analysis of Poly Chlorinated Biphenyl (PCB) congeners. The unique polarity of this phase gives excellent separation of PCB congeners

0.1 - 1.0 µm film thickness -20°C to 360/370°C

Column length: 10, 12, 25, 30, 50, 60 m
Column lD: 0.1, 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.1, 0.22, 0.25, 0.32, 0.53 µm

HT8 Optimized for PCB analysis
specifically designed for the separation of the 209 polychlorinated biphenyl congeners
pdf 635 KB
35% Phenyl Polysilphenylen-siloxane
BPX35

MS-Premium, low bleed columns with a maximum temperature up to 370°C. Especially suited for trace analysis of herbicides and aromatic columns

0.1 - 1 µm film thickness 10°C to 330/360°C

Column length: 10, 15, 25, 30, 50, 60 m
Column lD: 0.1, 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.1, 0.25, 0.5, 1.0 µm

Comparison of Structure and Retention on various 5 % Phenyl Phases
The advantages of BX5, BX35 and BX50 Phases when analysing aromatic compounds
pdf 1.3 MB
BPX608

optimized for ECD. I
i deal for the analysis of organochlorine herbicides and pesticides

0.32 µm film thickness 10° to 360/370°C

Column length: 25 m
Column lD: 0.32 mm
Film Thickness 0.4 µm

environmental analyses, EPA 608, pesticides/herbicides
50% Phenyl Polysilphenylen-siloxane
BPX50

MS-Premium, low bleed columns with a maximum temperature up to 370°C. Suited for a range of EPA methods and pharmaceutical applications

0.1 - 1µm film thickness 80°C to 360/370°C

Column length: 10, 15, 30, 60 m
Column lD: 0.1, 0.25, 0.15, 0.25, 0.32, 0.53mm
Film Thickness 0.05, 0.07, 0.1, 0.15, 0.25, 0.5, 1.0 µm

Comparison of Structure and Retention on various 5 % Phenyl Phases
The advantages of BX5, BX35 and BX50 Phases when analysing aromatic compounds
pdf 1.3 MB
70% Cyanopropyl Polysilphenylene-siloxane
BPX70

MS-Premium, low bleed columns with a maximum temperature up to 260°C. The polarity has been designed for Fatty Acid Methyl ester (FAME) analysis

0.1 - 1.0µm film thickness 50°C to 250/260°C

Column length: 10, 12, 15, 25, 30, 50, 60, 120 m
Column lD: 0.1, 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.2, 0.25, 0.5 µm

Approaches to The Analysis of Saturated and Mono-Unsaturated Fame Using Highly Polar Gc Phases
pdf 1.8 MB
90% Cyanopropyl Polysilphenylene-siloxane
BPX90

MS-Premium, low bleed columns with a maximum temperature up to 280°C. Extremely polar phase for the fast separation of aromatics, perfumes, petrochemicals and other compounds that are difficult to resolve using conventional columns

0.25 - 0.50 µm film thickness 80°C to 280°C

Column length: 15, 30, 60, 100 m
Column lD: 0.25, 0.32 mm
Film Thickness 0.25, 0.5 µm

BPX90 - Analysis of furan fatty acids in Fish
GCMS based structure assignment for furan fatty acids isolated from European Carp
pdf 1.8 MB
Polyethylene Glycol (PEG)
SolGel-WAX

robust, high temperature polar WAX phase. Less susceptible to damage by oxygen than conventional wax columns

0.25 - 1.0 µm film thickness 30°C to 260/280°C

Column length: 10, 15, 30, 60 m
Column lD: 0.1, 0.25, 0.53 mm
Film Thickness 0.25, 0.5 µm

recommended for highly active compounds
BP20 (WAX)

a very polar phase suited to the analysis of alcohols, ketones and aldehydes
also offers excellent separation of aromatic isomers such as the xylene isomers

0.1 - 1.0 µm film thickness 20°C to 260/280°C
> 1.0 µm film thickness 20°C to 240/260°C

Column length: 10, 12, 25, 30, 60 m
Column lD: 0.1,0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.1, 0.25, 0.5, 1.0, 2.0 µm

alcohol, free acids, fatty acid methyl esters, aromatics, solvents, essential oils
Treated Polyethylene Glycol (PEG)
BP21 (FFAP)

a very polar Nitroterephthalic acid modified PEG phase suited to the analysis of free fatty acids

0.25 -0.5 µm film thickness 35°C to 240/250°C

Column length: 12, 15, 25, 30, 50, 60 m
Column lD: 0.25, 0.32, 0.53 mm
Film Thickness 0.25, 0.5, 1.0 µm

volatile free acids, fatty acid methyl esters, alcohols, aldehydes, acrylates, ketones
14% Cyanoproylphenyl Polysiloxane
BP10 (1701)

this low bleed and highly inert phase has been selected with a polarity suited for the separation of organochlorine pesticides listed in the EPA 608 and 8081 methods

0.25 - 1µm film thickness -20°C to 280/300°C

Column length: 12, 15, 25, 30, 50, 60 m
Column lD: 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 0.25, 0.5, 1.0 µm

Environmental analyses (EPA methods 608 and 8081), pesticides/herbicides, drugs of abuse, pharmaceuticals
50% Cyanopropylphenyl Polysiloxan
BP225

mid to high polarity L
low bleed B
bonded and cross-linked phase

0.1 - 1.0 µm film thickness 40°C to 230/250°C

Column length: 25, 50 m
Column lD: 0.22, 0.32, 0.53 mm
Film Thickness 0.25, 0.5 µm

Fatty Acid Methyl Esters (FAMEs), carbohydrates, neutral sterols
Cyanopropylphenyl Polysiloxane (Volatiles)
BPX-VOLATILES

a polar phase used for EPA volatile organics analysis (EPA 624, SW-846 8240/8260), alcohol analysis and for USP G43

1.0 - 3.0µm film thickness 0°C to 290/300°C

Column length: 20, 30, 40, 60 m
Column lD: 0.18, 0.25, 0.32, 0.53 mm
Film Thickness 1.0, 1.4, 1.8, 3.0 µm

Environmental analyses, volatile organics, alcohol analysis, USP G43
BP624

US EPA 624 optimized column
designed for volatiles analysis
ideal for EPA624, SW-846 and 8240/8260 methods
ideal for USP G43 method

1.0 - 3.0µm film thickness 0°C to 230/240°C

Column length: 15, 25, 30, 50, 60 m
Column lD: 0.22, 0.25, 0.32, 0.53 mm
Film Thickness 1.2, 1.4, 1.8, 3.0 µm

EPA method 624, drinking water volatiles, chlorinated hydrocarbons, solvents
Permethylated Beta Cyclodextrin (Chiral)
CYDEX-B

Chiral columns for the separation of enantiomeric compounds found in natural products

30°C to 220/240°C

Column length: 25, 50 m
Column lD: 0.22, 0.32 mm
Film Thickness 0.25 µm

Separation of enantiomeric compounds found in natural products
GC Supplies
GC Capillary Columns
GC Syringes
GC Septa
Ferrules
Injector Liner
© infochroma ag, Chräbelstr. 4, CH-6410 Goldau; Tel: +41 41 748 50 60, info@infochroma.ch